specbos 2501

UV | VIS | NIR Spectroradiometer


Spectroradiometer JETI specbos 2501 is the further development of the successful specbos 1211-2 models as well as the spectraval series.

JETI specbos 2501 is a precise and fast broadband spectroradiometer covering the wavelength range of 380 nm ... 780 nm. In its basic configuration, the instrument measures spectral Radiance.
Spectroradiometer specbos 2501
Spectroradiometer JETI specbos 2501
It is possible to add the measurement mode Irradiance by attaching an optional diffusor.

Special versions of the device are specbos 2501-HiRes (with an increased optical resolution), specbos 2501-NIR (with a wavelength range up to 1000 nm), specbos 2501-UV (with extended wavelenght range from 230 nm to 1000 nm) and specbos 2501-LAN (with LAN interface instead of Bluetooth).

Spectroradiometer JETI specbos 2501
Spectroradiometer JETI specbos 2501
Back view of spectroradiometer JETI specbos 2501
Back view of spectroradiometer JETI specbos 2501
JETI specbos 2501: monitor measurement
JETI specbos 2501: monitor measurement
Spectroradiometer JETI specbos 2501
Spectroradiometer JETI specbos 2501

 

Highlights

  • Fast measurement of Radiance
  • Radiometric software JETI LiVal is included in the standard scope of delivery
  • Wavelength range 380 to 780 nm (standard model) and 200 to 1000 nm (specbos 2501-UV)
  • Optical bandwidth 4 nm/ 2 nm (specbos 2501-HiRes)
  • Measurement in Radiance (basic configuration) and Irradiance mode (diffusor required)
  • Start of measurement with external trigger signal
  • Highly sensitive
  • Internal target spot laser
  • Mechanical shutter for dark signal compensation
  • Automatic measurement in selectable time intervals
  • USB 3.0
  • LAN/ PoE (Power over ethernet)
  • Bluetooth

specbos 2501 is also available in the following special versions:

  Description Applications Interfaces Available
specbos 2501-UV Extended wavelenght range from 200 nm to 1000 nm
  • Risk classification of flood lights
  • UV measurements
  • Long term measurements of daylight and in green houses
USB3.0 and Bluetooth February 2024
specbos 2501-HiRes Increased optical resolution (FWHM 2 nm) USB3.0 and Bluetooth November 1st, 2023
specbos 2501-NIR Extended wavelength range from 380 to 1000 nm USB3.0 and Bluetooth November 1st, 2023
specbos 2501-LAN Additional LAN interface, e.g. for production environment USB3.0 and LAN November 1st, 2023
specbos 2501-UV Description
Extended wavelenght range from 200 nm to 1000 nm
Applications
  • Risk classification of flood lights
  • UV measurements
  • Long term measurements of daylight and in green houses
Interfaces
USB3.0 and Bluetooth
Available
February 2024
specbos 2501-HiRes Description
Increased optical resolution (FWHM 2 nm)
Applications
Interfaces
USB3.0 and Bluetooth
Available
November 1st, 2023

specbos 2501-NIR
Description
Extended wavelength range from 380 to 1000 nm
Applications Interfaces
USB3.0 and Bluetooth
Available
November 1st, 2023
specbos 2501-LAN Description
Additional LAN interface, e.g. for production environment
Applications
Interfaces
USB3.0 and LAN
Available
November 1st, 2023


For all specbos 2501 models the focus add-on is available.

Optical parameters
  • Spectral range:         380 … 780 nm
  • Optical bandwidth:   4 nm
  • Measuring range:     
    • Luminance 0.2 … 150 000 cd/m² (Illuminant A)
    • Illuminance  1 … 180 000 lx (Illuminant A)
      (higher values with optional filter)
Dimensions

PNGdrawing 2501.png

Measuring quantities
  • spectral Radiance
  • spectral Irradiance by attaching an optional diffusor
  • xy and u' v' coordinates
  • Dominant wavelength, Color purity
  • Correlated Color Temperature (CCT)
  • CRI, CQS, TM-30
  • Circadian metrics, PAR

All accessories of specbos 2501 are coded. The software switches to the related measuring mode and the appropriate calibration data will be used when an accessory was attached to the device.

Standard diffusor
The pure specbos 2501 measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.

90° diffusor
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range.

In axis remote diffusor
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.

90° remote diffusor
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.

Diffusors with attenuation filter
JETI specbos 2501 with its standard diffusor can measure up to about 1.500.000 lx (typical white LED spectrum). If it is necessary to measure higher Illuminances, then a special diffusor with additional attenuation filter can be used.

Dome
The dome is equipped with a glass dom and it is IP67 tested. It can be mounted on roofs or outside walls and allows a detection of the optical sky radiation.

Fast diffusors
If low Illuminance levels must be measured, then the measuring time will be long when using the standard diffusor of the device. It is possible to use “fast” diffusors, but only if the cosine matching of the diffusor is not of primary importance, e.g. in case of point like sources.

Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. specbos 1211-2 can be equipped with caps containing the filters of Dolby and realD projection. The usage of these filter pairs allows a precise measurement of these 3D projection system.

Neutral density filter
JETI specbos 2501 can measure up to 100 000 cd/m². An additional neutral density filter allows to shift the measuring range towards higher Luminance levels.

VIS filter
JETI specbos 2501 can be equipped with a VIS filter to reduce its wavelength range to 350 … 780 nm. This is especially interesting for measurements with a low VIS intensity but much signal in IR or UV.

Integrating spheres
To extend the functionality of JETI specbos 2501 to Radiant flux measurements, JETI offers three different models of integrating spheres.

Carrying case/ bag

Protective cap

Straylight protection tube
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements. The fixed length of the tube is 16 cm.

Tripod

Stray light correction matrix
In order to reduce stray light in array spectroradiometers while taking advantage of their portability, JETI offers a stray light correction matrix.

Light effects
Lamps
LED measurement
Display and projection measurement
General applications
Miscellaneous
  • Application of different color matching functions
  • Long term measurements of daylight and in green houses
  • Metameric calculation
  • Special new “Visual appearance” calculations
Documents
Datasheets

 iconPDFspecbos 2501.pdf (valid for all versions of the specbos 2501 series)

Documentation

iconPDFOperating Instructions JETI specbos 2501.pdf
iconPDFOperating Instructions JETI LiVal 7.x.pdf
iconPDFOperating Instructions Firmware Spectroradiometer.pdf

 

Software, Drivers and Firmware
Software JETI LiVal
  • Demo version
    • JETI offers you a demo version of JETI LiVal for testing. With the demo version you can get a first insight into the software.
      • iconZIP JETI LiVal DEMO V7.4.1 (121.3 MiB)
  • Full version
    • To download the full version of the software you have to be logged in (see in menu "Login").
    • Actual software version: V7.4.1
    • Download size: XX MiB

     JETI LiVal Changelog

Software JETI SDK
  • iconZIP JETI SDK V4.6.8 (4.9 MiB)
  • Actual software version: V4.6.8

     JETI SDK Changelog

Firmware
  • To download the firmware you have to be logged in (see in menu "Login").
  • Actual Firmware version: VERSION

     JETI specbos 2501 Firmware Changelog

Drivers
External software
JETI does not guarantee the function of JETI products with external software. JETI is not liable for any changes of external software. Please contact the supplier of the external software in case of any problem.

External software packages

Hardware related software