specbos 1211-BT-2

Wide range Spectroradiometer



specbos 1211-BT-2 is identical to specbos 1211-LAN-2. It has the same electronic and optical components. Instead of the LAN module, it is equipped with Bluetooth.

 

JETI specbos 1211-BT-2
Spectroradiometer JETI specbos 1211-BT-2
Front view of spectroradiometer JETI specbos 1211-BT-2
Front view of spectroradiometer JETI specbos 1211-BT-2
JETI specbos 1211-BT-2
JETI specbos 1211-BT-2
Back view of spectroradiometer JETI specbos 1211-BT-2
Back view of spectroradiometer JETI specbos 1211-BT-2
JETI specbos 1211-UV-BT-2: UV measurement during production
JETI specbos 1211-UV-BT-2: UV measurement during production

Highlights

  • Easy to use
  • Measurement in Radiance (basic configuration) and Irradiance mode (diffusor required)
  • Powered by USB and Bluetooth
  • Very fast measurement
  • Easy to install
  • Radiometric software JETI LiVal is included in the standard scope of delivery
Optical parameters
  • Spectral range:         350 … 1000 nm
  • Optical bandwidth:   4.5 nm
  • Measuring range:    
    • Luminance 0.2 … 150 000 cd/m2 (Illuminant A)
    • Luminance 0.2 … 100 000 cd/m2 (typical warm white LED)
      (higher values with optional filter)
Measuring quantities
  • Illuminance, Irradiance
  • xy and u' v' coordinates
  • Dominant wavelength, Color purity
  • Correlated Color Temperature (CCT)
  • CRI, CQS, TM-30, TLCI, RGB
  • Circadian metrics, PAR

specbos 1211-BT-2 can detect up to four accessories automatically, the software switches to the related measuring mode and uses the appropriate calibration data. More accessories have to be selected manually in the software.

Standard diffusor
specbos 1211-BT-2 measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.

90° diffusor
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range.

In axis remote diffusor
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.

90° remote diffusor
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.

Diffusors with attenuation filter
specbos 1211-BT-2 with its standard diffusor can measure up to about 1.500.000 lx (typical white LED spectrum). If it is necessary to measure higher Illuminances, then a special diffusor with additional attenuation filter can be used.

Dome
The dome is equipped with a glass dom and it is IP67 tested. It can be mounted on roofs or outside walls and allows a detection of the optical sky radiation.

Fast diffusors
If low Illuminance levels must be measured, then the measuring time will be long when using the standard diffusor of the device. It is possible to use “fast” diffusors, but only if the cosine matching of the diffusor is not of primary importance, e.g. in case of point like sources.

Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. specbos 1211-BT-2 can be equipped with caps containing the filters of Dolby and realD projection. The usage of these filter pairs allows a precise measurement of these 3D projection system.

Neutral density filter
specbos 1211-BT-2 can measure up to 100 000 cd/m². An additional neutral density filter allows to shift the measuring range towards higher Luminance levels.

Integrating spheres
To extend the functionality of JETI specbos 1211-BT-2 to radiation flux measurements, JETI offers three different models of integrating spheres.

Battery charger

Bluetooth USB adapter

BT antenna

Carrying case/ bag

Protective cap

Power supply

Replacement battery

Straylight protection tube
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements.

Tripod

Stray light correction matrix
In order to reduce stray light in array spectroradiometers while taking advantage of their portability, JETI offers a stray light correction matrix.

 

Software, Drivers and Firmware
Software JETI LiVal
  • Demo version
    • JETI offers you a demo version of JETI LiVal for testing. With the demo version you can get a first insight into the software.
      • iconZIP JETI LiVal DEMO V7.4.1 (121.3 MiB)
  • Full version
    • To download the full version of the software you have to be logged in (see in menu "Login").
    • Actual software version: V7.4.1
    • Download size: XX MiB

     JETI LiVal Changelog

Software JETI SDK
  • iconZIP JETI SDK V4.6.8 (4.9 MiB)
  • Actual software version: V4.6.8

     JETI SDK Changelog

Firmware
  • To download the firmware you have to be logged in (see in menu "Login").
  • Actual Firmware version: V3.4.12

     JETI specbos Firmware Changelog

Drivers

We use cookies
Essential Cookies

The essential cookies are always active. The website will not work without this. The essential cookies comply with all guidelines for the protection of your personal data.

Optional Cookies

However, some applications can only be guaranteed with the help of cookies, which could also forward your data to unsafe third countries. Their privacy policy applies to these applications:

  • YouTube (Videos)
  • Google Analytics

You can find out more about what cookies are and how they work in the privacy policy.

Do you agree to the use of all cookies?